Laminated glass traces its roots to a French chemist, 脡douard B茅n茅dictus, who in 1903 discovered a plastic interlayer that stuck to two pieces of glass.

Even when the glass was broken, the interlayer held the glass together. Although laminated glass was not commercialized until the 1930鈥檚, this Aha! moment has led the way for many exciting uses of safety glass.

The Early Years 鈥揝afety at the Forefront

Prior to 1998, the most common laminated glass interlayer was an extruded resin of polyvinyl butyral (PVB).  PVB was developed in the early 1930s by a joint R&D program consisting of scientists from DuPont, Libbey-Owens-Ford 电车无码 Co., Monsanto, Pittsburgh Plate 电车无码 (PPG), and Carbide and Carbon Chemicals Corp. (Union Carbide).  This material was flexible and durable, a safety upgrade to plate glass windshields. Laminated glass fabricators bonded two plies of glass together with PVB to create a monolithic unit that retained broken glass particles after breakage. 

In 1966, twenty-eight years after the first automotive safety glazing standard was passed, the ANSI Z97.1 standard for glass in buildings was published.  It was followed by the 1977 adoption of the Consumer Product Safety Commission (CPSC) federal regulation 16CFR 1201.

The CPSC standard specified a shot bag filled with one hundred pounds of lead shot as the test impactor.  Category I glazing was tested at a drop height of eighteen inches and Category II glazing was tested at 48 inches.  The standard was primarily focused on glazing in doors, glazing adjacent to doors, and in specific cases, glazed panels.  Either tempered or laminated glass could be used to comply with the standard as a means of reducing cutting or piercing injuries.

The ANSI Z97.1 standard and the 16CFR 1201 regulation are now part of the International Building Code Chapter 24. In addition, to the hazardous locations mentioned in the standard, the building code now contains a section on glazing in guards and railings that requires laminated glass.

Introduction of the SentryGlas庐 Interlayer

While safety glazing standards were designed to protect people, there were no standards to protect property subjected to extreme weather until a powerful, extremely destructive Category V hurricane hit South Florida in 1992.  Hurricane Andrew destroyed more than 63,000 homes and damaged more than 124,000 others. It was one of the costliest hurricanes in U.S. history. 

The initial solution to solve the glass breakage problem was laminated glass.  If the glass could be retained, even if broken, structures could avoid the buildup of internal pressures and the entry of water.  Unfortunately, the flexibility of PVB, a characteristic that worked so well for safety glazing, was a detriment to a large missile testing protocol for glazing within thirty feet of grade that called for impacts from a 9-pound 2 x 4 timber, followed by 9,000 positive and negative cycles of pressure. DuPont scientist Dr. Anthony Smith quickly recognized that a stiffer interlayer was needed, and that鈥檚 where SentryGlas庐 ionoplast interlayer found its first application.

At that time, it was known as SentryGlas庐 Plus (SGP) to reflect the added performance it offered over a PVB composite that was called SentryGlas庐.  Years later, the 鈥淧lus鈥 was dropped and the product has been known ever since as SentryGlas庐 or SG庐 interlayer.  This is the 25th Anniversary of this amazing interlayer and its use in laminates providing safety in impact systems around the world.

Certification of Hurricane Systems with SentryGlas庐

Unlike other testing requirements for glass and glazing, certification of products in South Florida became mandatory right from the start.  Successful testing enabled the issuance of a Notice of Acceptance (NOA), which meant the system was suitable for installation.  The certification component not only ensured confidence in product quality, but it gave homeowners and building managers a sense of security that their properties could survive a hurricane.

The ionoplast interlayer was tested in a variety of residential and commercial systems, and became a well understood interlayer offering excellent performance and quality.  The 35-mil product was used in small missile systems, 90-mil was typically used for large missile areas, and 180-mil interlayer was required for systems requiring enhanced performance compliance.  The make-up of the systems was transparent鈥攁ll details shown on each system鈥檚 NOA.

Crawford-Tracy 电车无码 Corporation, a turnkey glazing contractor in Deerfield Beach, FL was a leader in the development of impact systems. According to Company President Ray Crawford, 鈥淚n the early days, we spent a considerable amount of time testing systems to meet the impact and cycling requirements established by Dade County.  Ultimately, the SentryGlas庐 interlayer emerged as the best solution to pass the large missile test followed by cycling.   He notes, 鈥淲e have not seen any  delamination from the SentryGlas庐 laminates since we began installing the product.鈥

Today there are thousands of projects that utilize impact systems for hurricane protection in Florida.  These projects range from schools to hotels to hospitals to government buildings.  Ray Crawford noted that his company has provided impact glazing systems to hospitals throughout Florida.  They are also a supplier of glazing to essential facilities that require a higher level of impact testing.

Both new and existing buildings have benefited from impact systemsThe first three stories of Porsche Design Tower, a fifty-seven story ultra-luxury structure situated on beachfront land in Sunny Isles, Florida, used 90-mil SentryGlas庐 interlayer for large-missile impact protection.  A 35-mil SentryGlas庐 interlayer was used for small missile impact.  In addition, exterior balcony railings were also glazed with laminated glass. 

The Judicial Center and Courthouse, West Palm Beach, FL is an example of a 12-story building renovation where the existing fa莽ade frames were modified to incorporate new large missile glazing. The upgraded system used a reflective coating on the outside surface of an insulating glass unit and a 90-mil SentryGlas庐 laminated on the inboard.

The Future

The twenty-five year history of SentryGlas庐 has had a significant impact on the use of laminated glass in the hurricane market. The stiffness and strength of this product has enabled the development of windows and doors, storefronts, and curtainwall systems that offer 24/7 protection against extreme weather events.  The result has been safer living and working environments that do not require boarding up or the deployment of shutters if a weather alert is issued.  Building interiors are protected against water and wind infiltration and maintain a view to the exterior. 

Author: Valerie Block

600450 SentryGlas庐 - an excellent and unique solution for structural glass in the hurricane market 电车无码

Others also read

R.C.N. Solutions will exhibit in the Italian Piazza, representing one of the excellence present in the area.
We鈥檙e thrilled to announce the upcoming launch of Saflex LiteCarbon Clear.
This article, authored by Valerie Block, delves into the history, technological advancements, and the transformative impact of laminated glass over the decades.
Highly automated laminated glass line for oversized quality laminated glass
Continuing the journey of innovation with Glaston
POLFLAM is excited to announce its participation in FeuerTrutz 2024, a premier event where innovation meets fire protection.

Add new comment

From industry

Ottergemsesteenweg 707-Zuid
9000 Ghent
Belgium

Pol. Ind. Penapurreira Parcela C4-B,
15320 As Pontes de Garc铆a Rodr铆guez A Coru帽a
Spain

No. 160 Yichuan Rd.,
Jiaonan Shi
Qingdao Shi
Shandong Sheng, 266000
China

NEWS RELATED PRODUCTS